The durable RIGID 30 Lock vinyl floors from Gerflor have an ultra-realistic surface, are dimensionally stable and suitable for damp rooms.
- Robust and highly functional Rigid middle layer. The middle layer consists of a rigid Rigid Vinyl core. This makes the floor waterproof and extremely resistant. Accordingly, the floor is also suitable for rooms with floor-to-ceiling windows (direct sunlight should nevertheless be limited).
- Natural and authentic surface The vinyl floor gets its natural look from natural surface embossing. In addition, it has been treated with a matt PUR+ layer and chamfered at the edges, which further emphasises the natural design.
- Can be laid on almost all subfloors
Gerflor, a leading flooring manufacturer, has a 70-year history of producing resilient floor coverings for residential and commercial applications. The French company was founded in Lyon in 1937 and always focused on innovation, healthy materials and aesthetic floor design when developing new flooring solutions. Gerflor is right about its success - numerous awards attest to the first-class quality, the design, and the environmentally friendly aspect of Gerflor products. The Red Dot Award competition honors Gerflor's Creation 70 with the Red Dot Award for Product Design 2016.
item no. | 36300011 |
---|---|
Manufacturer | Gerflor |
Collection | Rigid Lock 30 |
Length in mm | 914 |
Width in mm | 457 |
Thickness in mm | 4 |
Wear layer | 0,30 mm |
Wear class | 31 Commercial (light) |
Joint | Beveled edge (4 sides) |
Warranty | 12 Jahre Privat |
suitable for | Bath, Kitchen, Bedroom & living room, Hallway & Corridor |
installation pattern | Tile format |
Installation type | click |
Look | Stone effect |
Sorting (grain) | lively/rustic |
Underfloor heating | suitable |
Special features | Non-slip |
EAN | 3475710440748 |
Piece per package | 5 |
Structure | Rigid SPC |
Slip resistance | R10 |
Shipping group | M |
Colour | black |
Range of application | Residential, Commercial |
Style | Modern |
Weight | 16,49 kg/Packing |
Package Content | 2.09 m² |
Show all data ▼
|
|
Downloads | |
![]() |
|
![]() |
We will help you with your questions!
A specialist adviser will be happy
to advise you personally.
☎ +49 5222 960 4810
Mon - Fri: 9am - 6pm
Sat: 9am - 2pm
Variant: DIY Instruction

Check the subfloor. Any unevenness that exceeds 3 mm over a length of 1 m should be sanded down or filled with a floor levelling compound. Then clean the surface to be laid with a hoover.
CAUTION: Never install vinyl over a soft subfloor such as carpet, cork or any type of foam underlay.

The vinyl planks should be stored horizontally in the room where it is to be installed for at least 48 hours before installation in the packages. This will allow the material to acclimatise to the room temperature and not "work" so hard after installation.

Before laying the floor, it is imperative to follow the official laying instructions, which are included in every package, otherwise any claim to warranty and guarantee will be void!
Before laying out the floor, check the wall you are starting on and make sure it is at right angles to the opposite wall. If the impact sound insulation is not already integrated, we now recommend spreading out the insulation.

Tips for the UniClic system: To achieve as uniform a floor appearance as possible, it is recommended to install panels from different packages mixed together. You should start laying in a corner (left) and starting from the wall. With the tongue side facing the wall, lay the first board. Angle the end of the second board into the first. In the second row, the plank is placed at an angle to the end face of the row already laid and folded down. As the board is folded down, the long side of the board will click into the existing board at an angle. With a little pressure, the click joints now snap into place. The transverse joints (front side) should be offset by at least 30 cm from row to row ("wild bond", half a plank length for tile formats). You can use a tapping block and a light tap on the long side of the plank to help it along. To cut a plank, now take measurements and mark the plank. Then take an angle and tear the plank with a multi-purpose knife/cutter and break it off.

Place the spacers on walls, door frames, fixed wall cabinets, kitchen units, etc. so that you have an expansion gap of approx. 5-10mm for underfloor movement or expansion of the product. To install the last row, it is recommended to use the floor layer's jointing iron from the accessories. When using skirting boards, make sure that the expansion joint is covered by the skirting board. If the floor is sealed, e.g. in the bathroom, the PE round cord is now inserted into the expansion joint and the floor sealed with a silicone joint.

Finally, cut off the PU film approx. 2 cm high and attach the skirting boards.
Material:
- Click vinyl flooring
- Impact sound insulation
Tools:
- Cutter knife
- Angle
- Pencil
- Hammer
- Rubber mallet
- Measuring tape
- Spacer
optional:
- Skirting boards
- PE vapour barrier*
Working time:
- for a room size of 15-20 m² approx. 4-5 hrs.
Difficulty level:
- easy
*required for floors with HDF core board and cork impact sound insulation
Click vinyl flooring installation guide
Laying vinyl flooring on tiles, how wide and deep can the joint be?
Laying vinyl flooring on tiles - planeo Sly
Click or stick vinyl flooring
Is click vinyl waterproof and usable in the bathroom?
Subfloor testing before laying flooring
The 10 most common mistakes when laying vinyl flooring - is it possible?
Laying vinyl flooring over old floorboards
Damp room flooring for bathrooms - sealing the floor covering
Filling uneven tiles and joints
Laying the floor on the heating pipe
Vinyl flooring wear layer 0.3 or 0.5mm. Does a high wear layer protect against scratches?
Individual offer?
Are you looking for a lower price? Just ask us for an individual offer!